The AS-200 green line cooling system is suitable for smaller restaurants, bars, guest facilities and also works great for home use. This cooler has a performance of 140-200 l/h.
The circulation pump in the water bath ensures an even temperature, it can also be used for cooling the python hose between as-80 and beer tower. Maximum height difference 7 meters. The overfill protection on the side ensures that the water bath is not overfilled.
The products in the "green lineseries are environmentally friendly and have a 20% higher energy efficiency and 20% lower energy consumption. The cooler is made exclusively of recyclable materials and without polyurethane insulation.
The materials used meet the highest standards of good hygiene standards and guarantee a long service life. The cooling coils are made of stainless steel. Two handles on the side of the machine make it easy to handle.
Combine with any beer tower from our range and please contact us for help with a complete package.
Technical information
Type Of Refrigerant |
R290 |
Rated Current (a) (A) |
3.4 |
Voltage |
220-240V 50Hz ~1 |
Power consumption (W) |
782 |
Output (l/h) To 0 ° C / Tk 50 ° C |
200 |
Number of cooling coils |
4 |
Length cooling coil (m) |
14/14/10/10/9,5/9,5/9,5/9,5 |
Net weight (kg) |
39 |
Volume water bath (l) |
58 |
Diameter cooling coils (mm) |
8x0.5 |
Dimensions (BxDxH mm) |
661x423x539 |
Maximum height difference circulation pump (m) |
8 |
A draught beer cooler or water plant needs to be moved in in the autumn if there is a risk of temperatures below 5 degrees otherwise it risks freezing. If the machine is in a frost-free space, it can remain. It is easy to unplug the machine and move it. If an external tap tower is used, the taps should be unscrewed and the tap tower itself covered with a plastic bag or similar.